Home > Products > Fire Pump > Fire Pump System with two Jockey Pump
Fire Pump System with two Jockey Pump
  • Fire Pump System with two Jockey PumpFire Pump System with two Jockey Pump

Fire Pump System with two Jockey Pump

Shanghai Crowns Pump Manufacturing Co., Ltd. delivers a reliable Fire Pump System featuring two jockey pumps, designed to maintain stable water pressure during fire emergencies. This efficient setup includes a pressure tank and control panel, ensuring optimal performance without main pump activation—critical for early-stage fire response. The dual-jockey design offers redundancy, auto-switching between pumps to sustain pressure and minimize maintenance downtime. Ideal for high-rises, industrial sites, and public buildings, it meets safety standards with quiet operation (≤75 dB) and space-saving integration. Trust our solution for proactive fire readiness, combining durability and smart control to safeguard assets and ensure compliance in emergency scenarios.

Send Inquiry

Product Description

The Pressure Maintenance System, developed to support modern fire protection infrastructures, combines efficiency, precision, and durability. This integrated setup utilizes two electric jockey pumps, a pressurized water tank, and an intelligent control panel to maintain consistent pressure throughout the fire suppression network. Designed to prevent unnecessary activation of the main fire pumps, it is ideal for facilities that demand stable water pressure under both standby and operational conditions.

System Components

  • Dual Electric Jockey Pumps

Two high-efficiency jockey pumps operate alternately or simultaneously to offset minor pressure fluctuations. These compact units ensure that the fire protection system remains at optimal pressure levels without engaging the main fire pump unnecessarily, reducing wear and energy consumption.

  • Pressurized Storage Tank

The system includes a pressure tank that acts as a buffer against sudden pressure changes. By storing pre-pressurized water, it smooths system fluctuations and minimizes pump cycling, contributing to energy savings and component longevity.

  • Smart Control Panel

The control system continuously monitors pipeline pressure and automatically activates or deactivates the jockey pumps as required. This electric jockey pump with controller not only ensures precision operation but also provides alarms, status displays, and protection features for enhanced operational safety.

  • Durable & Compact Design

The system, which includes a fire pump system with two jockey pumps, is built with corrosion-resistant materials, allowing it to perform reliably in a range of environmental conditions. Its integrated layout simplifies both installation and ongoing maintenance, even in tight spaces.

Operating Parameters

  • Power Requirements:

Standard input is 380V/50Hz. Other power configurations can be customized to suit project-specific requirements.

  • Environmental Conditions:

Recommended ambient temperature: 0°C to 40°C

Best installed indoors in a dry, ventilated location

Special configurations available for extreme climates

  • Water Medium Compatibility:

Suitable for clean water and mildly corrosive liquids. Fluid temperature should remain below 80°C. Not recommended for liquids containing abrasive solids or highly corrosive chemicals.

  • Pressure Range:

Engineered to maintain pressure between 10 and 16 bar, with a maximum working capacity of up to 25 bar, depending on the system model and design application.

Key Applications

The fire pump system with two jockey pumps is ideal for maintaining steady system pressure across a broad range of fire protection installations:

  • Commercial and High-Rise Buildings

Keeps sprinkler and hydrant systems fully pressurized, ensuring instant readiness in office towers, hotels, and apartment complexes.

  • Industrial Complexes

Maintains pressure for large-scale manufacturing and warehouse facilities where equipment reliability is essential.

  • Public Infrastructure & Transportation Hubs

Delivers stable pressure in large public venues like airports, train terminals, and convention centers—locations where response time is critical.

  • Energy Plants & Chemical Zones

Especially suited for hazardous environments where fire system integrity is vital. Helps minimize risk in power generation stations, refineries, and chemical factories.

  • Subterranean Projects & Tunnel Networks

Ensures pressure stability in underground environments such as metro systems, tunnels, and underground parking facilities.

Conclusion

This upgraded Pressure Maintenance System featuring an Electric Jockey Pump with Controller is engineered to offer precision control, operational reliability, and long-term durability. Its modular, compact design makes it ideal for integration into both new and existing fire protection systems, giving facility managers confidence in maintaining critical pressure levels without unnecessary strain on the main pump units.

For technical drawings, model selection support, or project-specific customization, please contact our technical sales team.



Fire Pump System with two Jockey Pumps

Hot Tags: Fire Pump System with two Jockey Pump, China, Manufacturer, Supplier, Factory, Quality
Related Category
Send Inquiry
Please feel free to give your inquiry in the form below. We will reply you in 24 hours.
X
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
Reject Accept